ISMRM 2023 Presentations

Hyperfine, Inc. is located in booth D28 at ISMRM 2023.

Monday, June 5

Program Number: 1586
Location: Exhibition Halls D/E (Computer 122)
Start / End: 8:15–9:15
Session Name: Low-Field & Point-of-Care/Portable MRI I
Title: Magnetization Transfer Imaging using non-balanced SSFP at Ultra-Low Field.
Authors (Affiliations): Balaji et al. (University of British Columbia, Hyperfine, Inc., King’s College London, Bill & Melinda Gates Foundation, and Lund University)



Program Number:
1588
Location: Exhibition Halls D/E (Computer 124)
Start / End: 8:15–9:15
Session Name: Low-Field & Point-of-Care/Portable MRI I
Title: On the estimation of age-related volumetric brain changes using ultra-low field MRI images.
Authors (Affiliations): Hsu et al. (New York University Grossman School of Medicine)



Program Number:
1595
Location: Exhibition Halls D/E (Computer 131)
Start / End: 8:15–9:15
Session Name: Low-Field & Point-of-Care/Portable MRI I
Title: Point-of-Care Knee MRI at 0.064T: Expanded Evaluation and Initial Comparison with Clinical Knee MRI at 3T
Authors (Affiliations): Watchmaker et al. (Icahn School of Medicine at Mount Sinai and Harvard Medical School)



Program Number:
104
Location: Power Pitch Theatre 2
Start / End: 8:15–9:15
Session Name: Pitch: Novel Acquisition Strategies
Title: Tensors and Tracts at 64 mT.
Authors (Affiliations): Plumley et al. (Cardiff University, Hyperfine, Inc., and University College London)



Program Number:
1773
Location: Exhibition Halls D/E (Computer 134)
Start / End: 9:15–10:15
Session Name: Low-Field & Point-of-Care/Portable MRI II
Title: Improved T1w Imaging at Ultra-Low Field by use of phase-sensitive reconstruction.
Authors (Affiliations): Lecurieux Lafayette et al. (King’s College London and Hyperfine, Inc.)



Program Number:
2526
Location: Exhibition Halls D/E (Computer 178)
Start / End: 17:00–18:00
Session Name: Pediatric Neuroimaging
Title: Clinical Utility of Optimised Ultra-Low Field Structural MR Brain imaging in Neonates.
Authors (Affiliations): Cawley et al. (King’s College London, Evelina Children’s Hospital, and Hyperfine, Inc.)



Program Number:
307
Location: 717A/B
Start / End: 17:04–17:12
Session Name: Low-Field & Point-of-Care/Portable MRI
Title: Ultra-Low Field Quantitative T2 Mapping.
Authors (Affiliations): Dvorak et al. (University of British Columbia, Hyperfine, Inc., CaliberMRI, Inc., King’s College London, Bill & Melinda Gates Foundation, and Lund University)

Wednesday, June 7

Program Number: 3712
Location: Exhibition Halls D/E (Computer 132)
Start / End: 8:15–9:15
Session Name: ML/AI for Acquisition & Reconstruction I
Title: Super resolution imaging from low-field strength scanners using generative adversarial networks.
Authors (Affiliations): Arnold et al. (University of Pennsylvania, National Institute of Neurological Disorders and Stroke, and Hyperfine, Inc.)



Program Number:
3624
Location: Exhibition Halls D/E (Computer 40)
Start / End: 8:15–9:15
Session Name: DTI & DWI I
Title: Super-resolution diffusion tensor imaging at 64 mT.
Authors (Affiliations): Plumley et al. (Cardiff University)

Thursday, June 8

Program Number: 4598
Location: Exhibition Halls D/E (Computer 3)
Start / End: 8:15–9:15
Session Name: Signal Modeling
Title: Multi-Continent Analysis of Geometric Distortion in Low-Field MRI.
Authors (Affiliations): Ogier et al. (National Institute of Standards and Technology, Massachusetts General Hospital, Harvard Medical School, National Institute of Standards and Technology, Yale University School of Medicine, CURE Children’s Hospital of Uganda, Mbarara University of Science and Technology, and Hyperfine, Inc.)



Program Number:
4906
Location: Exhibition Halls D/E (Computer 138)
Start / End: 9:15–10:15
Session Name: Multicontrast MRI: Applications & Phantoms
Title: Sampling Time Considerations for T1 map acquisition on the 64mT Hyperfine, Inc. Swoop system: A Phantom Evaluation Study.
Authors (Affiliations): Nguyen et al. (Illinois Institute of Technology, Hyperfine, Inc., and University of Chicago Medical Center)



Program Number:
5088
Location: Exhibition Halls D/E (Computer 146)
Start / End: 13:45–14:45
Session Name: Phantoms & Repeatability I
Title: Modeling and selection of T1 and T2 tissue mimics for 0.0065T, 0.064T, 0.55T MRI using agarose with manganese, gadolinium, copper, or nickel.
Authors (Affiliations): Jordanova et al. (NIST: National Institute of Standards and Technology, University of Southern California, Massachusetts General Hospital and Harvard Medical School, and Hyperfine, Inc.)



Program Number:
1364
Location: Power Pitch Theatre 2
Start / End: 13:45–14:45
Session Name: Pitch: Relaxometry & Multicontrast MRI: From Cancer to White Matter & More
Title: Reproducibility and sensitivity of in vivo human brain R1 map at ultralow field 64 mT
Authors (Affiliations): Kim et al. (National Institute of Health)

Hyperfine Swoop COB

The Swoop® system brings MR brain imaging within reach.

The Swoop system brings brain imaging within reach for clinicians to help them make clinical decisions in a variety of healthcare settings across a range of conditions. The first FDA-cleared portable MR brain imaging system that combines safe, ultra-low-field magnetic resonance with proprietary artificial intelligence, the Swoop system potentially enables timelier treatment decisions, quicker discharges, and more efficient use of staff and hospital resources.

Learn More arrow icon